40 Operation Theorem
4.4.3 Position Compare
The PCI-8136M provides position compare function for all six pulse input
channels. Once the counter value is reached the pre-set compare value, an
interrupt signal will be generated immediately. This function can
effectively reduce the overhead of CPU's polling for current position.
Related functions:
_8136_S_Set_Int_Factor() : please refer to section 5,9
_8136_P_Set_Compare_Value(): please refer to section 5.8