Registers 33
4.12 Interrupt Status Register
Address: BASE + 0x38
Attribute: read
Data Format:
Bit 7 6 5 4 3 2 1 0
--- --- --- Timer STTC
Hfull DTrg EOC
Bit 15 14 13 12 11 10 9 8
--- --- --- --- --- --- --- ---
Bit 23 22 21 20 19 18 17 16
--- --- --- --- --- --- --- ---
Bit 31 30 29 28 27 26 25 24
--- --- --- --- --- --- --- ---
Table 17. Interrupt Status Register
Timer (bit4): GPTC generated Interrupt status
1: Interrupt Occurs
0: Interrupt not Occur
SCTC(bit3): Scan Counter reach Terminal Count Interrupt status
1: Interrupt Occurs
0: Interrupt not Occur
HFull (bit2): data FIFO Half Full Interrupt
1: Interrupt Occurs
0: Interrupt not Occur
DTrg (bit1): Digital Trigger Interrupt status
1: Interrupt Occur
0: Interrupt not Occur
EOC (bit0): End of Conversion Interrupt status
1: Interrupt Occurs
0: Interrupt not Occur